• AC controlled welding power supply: MEA-100A

AC controlled welding power supply: MEA-100A

Best for precision resistance welding of small parts.
Model : MEA-100A

  • Clear display with LED.
  • Up to thirty one schedules can be set.
  • Easy setting by seven press keys.
  • Four welding control systems: Multiple cycle welding/ secondary constant current control, multiple cycle welding / voltage compensated control, single cycle welding/ voltage compensated control, and half cycle welding / voltage compensated control.
  • An automatic maximum current configuration.

    The maximum current setting is automatically configured through test run to optimize the performance of the device.

  • The welding current is monitored using the a toroidal coil.

    The upper and lower current limits can be fixed. This will aid the quality control.

  • Support for export.

    CE and CCC supported. There are also 480V version for USA.

Model MEA-100A
Power requirement * Single-phase Automatic switching (The voltage can be switched, but the factory setting is fixed.)
Maximum capacity 20kVA (10% duty cycle, 200VAC Input) / 26kVA (10% duty cycle, 400VAC Input) / 31kVA (10% duty cycle, 480VAC Input)
Control method 1. Secondary constant current control type
2. Power supply voltage fluctuation compensation control type
Welding current control 1. Multi - cycle welding
2. Single - cycle welding
3. Half - cycle welding
Control speed Half - cycle
Current accuracy For secondary constant current control ±2% max. of power supply voltage fluctuation ±10% ±2% max. of load fluctuation ±10%
±2% max. of load fluctuation ±10%
For power supply voltage fluctuation compensation control ±3% max. of power supply voltage fluctuation ±10%
Timer setting (31 schedules) Multi - cycle welding Squeeze, weld 1, cool, weld 2, hold ... 0 - 99cycles Upslope 1, upslope 2, downslope 0 - 9cycles Pulsation 1 - 9times
Single - cycle welding Squeeze, 0 - 99cycles First-half wave, second-half wave 0.5cycle
Half - cycle welding Squeeze, 0 - 99cycles Half wave 0.5cycle
Current value setting range (31 schedules) For secondary constant current control Current value 1, current value 2 ... 0.20 - 9.99kA (0.01kA unit)
For power supply voltage fluctuation compensation control Current value 1, current value 2 ... 0.0 - 99.9kA (0.1% unit)
Current monitoring (31 schedules) For secondary constant current control Upper limit setting: +1 to +49% Lower limit setting: -1 to -49%
For power supply voltage fluctuation compensation control Upper limit setting: 0.01 - 9.99kA (0.01kA unit) Lower limit setting: 0.01 - 9.99kA (0.01kA unit)
Options Toroidal coil MB-35E (Required for secondary constant current control)
Ambient temperature and huidity Temperature = 0 to 45°C Humidity = 90% max.(No condensation)
Power consumption For standby 15W max.
Mass 6.5kg
  • * Set at the factory

mea-100a-1.png



Model MT-510AC MT-520AC MT-530A MT-25
Rated capacity 1.0kVA 3.2kVA 6kVA 15kVA
Rated primary voltage 200VAC +/-10%
Rated secondary voltage 1.2/ 1.8/ 2.5/ 3.5V 2.5/ 3.2/ 4.0/ 5.0V 2.7/ 3.4/ 4.3/ 5.3V 2.6/ 4.0V (paralell)
5.3/ 8.0V (straight)
Input frequency 50/60Hz
Maximum output current 1600A 3700A 6600A 8000A
Duty factor (@100ms) 1.5% or below
Cooling method Air cooling Water cooling
Dimensions and Mass 193W x 291D x 176H mm / 20kg 182W x 358D x 198H mm / 35kg 225W x 364D x 244H mm / 44kg 180W x 370D x 240H mm / 60kg