For DC spot welding/fusing ISB-600A
-
◆Interrupt feature
Interrupt feature functions when a displacement amount reaches up to set level and stops current to obtain stable fusing. For this feature, it needs to be connected with a weld checker with a built-in displacement monitor and set a displacement amount of electrodes beforehand.
-
◆Six kinds of control methods
Select an optimal control method for an application: Primary current effective value control, secondary current effective value control, secondary power effective value control, Primary current peak value control, secondary voltage effective value control, and constant phase control.
-
◆Three kinds of monitoring
Current, voltage, or power can be monitored.
-
◆Safety features
Overcurrent detector, no-current/no-voltage detector, heat abnormality detector, and self-check feature protect your safety.
-
◆Two kinds of welding time unit
ms or cycle can be selected.
Model | ISB-600A-00-00 | ||
---|---|---|---|
Power requirements |
200 to 240V +/-10%, 50/60Hz, Three phase |
||
Maximum output current | 600A (3%) | ||
Number of schedule | 255 | ||
Output frequency | 1kHz | ||
Control method |
Primary constant current effective value / secondary constant current effective value / secondary constant current effective value / primary constant current peak value / secondary constant voltage effective value / constant phase |
||
Timer | ms mode / cycle mode | ||
SQUEEZE | 0000 to 9999ms / 000 to 999cyc | ||
SQUEEZE DELAY | 0000 to 9999ms / 000 to 999cyc | ||
SQUEEZE | 0000 to 9999ms / 000 to 999cyc | ||
UP SLOPE 1, 2, 3 | 000 to 400ms / 00 to 20cyc | ||
WELD 1, 2, 3 | 000 to 600ms / 00 to 30cyc | ||
DOWN SLOPE 1, 2, 3 | 000 to 400ms / 00 to 20cyc | ||
COOL 1, 2 | 000 to 999ms / 00 to 99cyc | ||
HOLD | 00000 to 20000ms / 000 to 999cyc | ||
OFF | 0 or 0010 to 9990ms / 00 to 99cyc | ||
Turns ratio of transformer | 1.0 to 199.9 | ||
Pulsation | 01 to 19 | ||
Setting range
|
|
||
Mass | 31kg |
The values in brackets are of ISB-600A.
For ISB-600A
Model
ITE-1500A3
SIT-F241-HC
Power requirements
220VAC
220VAC
Rated capacity
47.4kVA (50%)
75kVA (50%)
Rated primary voltage
300V
No-load secondary voltage
13V / 15V
12.5V
Maximum output current
10000A (5%)
12000A (5%)
Cooling method
Air cooling
Water cooling
Ambient temperature
5 to 40°C
Dimensions and mass
278H x 217.5W x 490D mm / 46.5kg
180H x 240W x 480D mm / 35kg